Cases reported "Vascular Fistula"

Filter by keywords:



Filtering documents. Please wait...

1/240. In situ repair of a secondary aortoappendiceal fistula with a rifampin-bonded Dacron graft.

    Secondary aortoenteric fistulas remain challenging diagnostic and therapeutic problems. Although the duodenum is most frequently involved, other intestinal segments are possible sites for fistulization. We report here a case of graft-appendiceal fistula revealed by recurrent gastrointestinal bleeding 11 years after abdominal aortic aneurysm replacement. The preoperative diagnosis was not achieved by endoscopy or imaging assessment. Despite recommended principles of total graft excision and extraanatomic bypass, appendectomy and in situ rifampin-bonded graft reconstruction were performed because of the advanced age and poor arterial runoff. The postoperative course was uneventful and the patient remains well 17 months after operation.
- - - - - - - - - -
ranking = 1
keywords = aneurysm
(Clic here for more details about this article)

2/240. Aorto--bronchial fistula resulting from an accidental fall one year earlier.

    A 75-year-old woman presented with massive haemoptysis 12 months after tripping over her shopping trolley. CT scanning and transoesophageal echocardiography demonstrated a traumatic false aneurysm which was confirmed at surgery to be partially ruptured. Aortobronchial fistula is an unusual cause of massive haemoptysis. It should be considered particularly in patients known to have abnormalities of the thoracic aorta.
- - - - - - - - - -
ranking = 1
keywords = aneurysm
(Clic here for more details about this article)

3/240. Primary aortoduodenal fistula.

    The aortoenteric fistula is a well-known but uncommon cause of gastrointestinal haemorrhage. It is usually secondary to previous reconstructive surgery of an abdominal aortic aneurysm. Primary aortoenteric fistula is a rare disorder which predominantly occurs in the duodenum. We report the case of a 76-year-old patient who presented with melaena and hypovolaemic shock due to a primary aortoduodenal fistula. Pathogenesis, diagnostic procedures and postmortem pathologic examination of this condition are discussed. The value of computed tomography in establishing the diagnosis is emphasized.
- - - - - - - - - -
ranking = 1
keywords = aneurysm
(Clic here for more details about this article)

4/240. Primary aorto-duodenal fistula secondary to infected abdominal aortic aneurysms: the role of local debridement and extra-anatomic bypass.

    Gastrointestinal bleeding secondary to spontaneous rupture of an infected abdominal aortic aneurysm into the duodenum is a rare and highly lethal clinical occurrence, representing roughly a third of all primary aortoduodenal fistulas. diagnosis is problematic due to the subtleties in the clinical presentation and course, and surgical treatment is usually delayed, representing a challenge even for the experienced vascular surgeon. The overall mortality is over 30% and the operative approaches are still controversial. Two cases of ruptured infrarenal aortic aneurysms complicated with aortoduodenal fistula were recently treated at our institution. Bacterial aortitis was documented by arterial wall cultures positive for klebsiella and salmonella species respectively. The clinical courses and outcomes of the two patients (one survivor ) treated with retroperitoneal debridement and extra-anatomic bypass and a review of the modern surgical treatment are herein described.
- - - - - - - - - -
ranking = 6
keywords = aneurysm
(Clic here for more details about this article)

5/240. hematuria from arteriovesical fistula: unusual presentation of ruptured iliac artery aneurysm.

    iliac artery aneurysm rupture can be rapidly fatal if not diagnosed immediately. These aneurysms usually present in patients with other aneurysmal diseases of the aortoiliac arterial system. If not diagnosed and surgically repaired, iliac artery aneurysms can proceed to expand and ultimately rupture, usually presenting with back, flank, or abdominal pain and, possibly, signs of systemic shock. We present an unusual case report of a common iliac artery aneurysm rupture presenting as gross hematuria due to an arteriovesical fistula. Only three other cases of arteriovesical fistulae have been reported previously. Unlike the case presented, all three of these cases involved trauma or surgical instrumentation or manipulation of the bladder.
- - - - - - - - - -
ranking = 9.0677188078456
keywords = aneurysm, artery, artery aneurysm
(Clic here for more details about this article)

6/240. Delayed massive hemoptysis after expandable bronchial stent placement.

    patients with lung cancer often develop airway obstruction that necessitates palliative bronchoscopic interventions. Expandable metal stents are increasingly used for this indication. We report a case of fatal massive hemoptysis that occurred 1 week after uneventful bronchial stent placement. Previous treatment with external-beam radiotherapy, brachytherapy, and photodynamic therapy probably contributed to pulmonary artery-bronchial fistulization in this patient. This complication should be kept in mind when considering expandable airway stent insertion in heavily pretreated lung cancer patients.
- - - - - - - - - -
ranking = 0.0048507128027682
keywords = artery
(Clic here for more details about this article)

7/240. Successful surgical treatment of aortogastric fistula after an esophagectomy and subsequent endovascular graft placement: report of a case.

    An aortogastric fistula is a rare but fatal complication after an esophagectomy and intrathoracic esophagogastric anastomosis. A 54-year-old man underwent an esophageal resection due to carcinoma in his lower esophagus. The alimentary tract continuity was restored by intrathoracic esophagogastric anastomosis. Forty-six days later, he suffered a massive hematemesis due to an aortogastric fistula which had formed at the esophagogastric suture line. The fistula was surgically obliterated twice, but each operation was followed by pseudoaneurysm formation. The patient was finally successfully treated with an endovascular stent graft placement. This is the first report of a patient surviving after developing this complication.
- - - - - - - - - -
ranking = 1
keywords = aneurysm
(Clic here for more details about this article)

8/240. Aortoduodenal fistula arising from the dilatation of a knitted Dacron graft: report of a case.

    A fatal aortoduodenal fistula occurred in a 72-year-old man who underwent a repair of an abdominal aortic aneurysm 16 years previously with a 20 x 10 mm bifurcated knitted Dacron graft. The aortic part of his bifurcated graft had dilated to 40 mm in diameter, with a discrepancy of 20 mm in the diameter between the graft and infrarenal aorta. The fourth portion of the duodenum adhered to the left side of the anastomosis, where the aortoenteric fistula had occurred. We believe that the graft dilatation was the cause of the anastomotic failure, although other factors such as atherosclerotic degeneration of the host aorta should also be considered. Knitted Dacron grafts that have been implanted for more than 10 years should therefore be monitored carefully because they have an inherent tendency to dilate, especially those manufactured before 1981.
- - - - - - - - - -
ranking = 1
keywords = aneurysm
(Clic here for more details about this article)

9/240. Complete resolution of post-traumatic high-flow priapism with conservative treatment.

    The most frequent cause of high-flow priapism is penile or perineal closed trauma with laceration of the cavernous artery and the formation of an arterial-lacunar fistula. We present the case of a high-flow priapism due to closed perineal trauma and damage to the left cavernous artery which completely resolved following conservative treatment. The case was documented by duplex Doppler ultrasound and selective pudendal arteriogram before and after resolution.
- - - - - - - - - -
ranking = 0.0097014256055363
keywords = artery
(Clic here for more details about this article)

10/240. Aortoduodenal fistula: a late complication of intraluminal exclusion of an infrarenal aortic aneurysm.

    During recent years, considerable clinical experience has been gained with endoluminal stent-graft procedures. Several studies have shown promising results up to a period of 4.5 years. However, long-term follow-up studies are still limited. Late endoleaks caused by stent-graft migration, disconnection of single components in modular stent-grafts, and limb thrombosis have been observed as long-term complications. We report a case in which a migrated and kinked bifurcated stent-graft caused an aortoduodenal fistula 20 months after stent-graft insertion. To our knowledge, such a complication has not been reported before.
- - - - - - - - - -
ranking = 4
keywords = aneurysm
(Clic here for more details about this article)
| Next ->