1/2. Allograft bone in spinal fusion for adolescent idiopathic scoliosis.

    OBJECTIVE: The purpose of this long-term study was to determine the efficacy of allograft bone for spinal fusion for adolescent idiopathic scoliosis. Prior studies comparing allograft and autograft have been short term. methods: This multicenter retrospective study was carried out on 111 patients with 132 total curves fused for adolescent idiopathic scoliosis. Minimum follow-up was 5 years (average 72 months). A variety of segmental instrumentation was used, with most being dual-rod, multiple-hook constructs. RESULTS: Average preoperative curve was 59 degrees with immediate correction to 29 degrees (51%) and final follow-up of 32.24 degrees (45.4%). Average loss of correction was 3.5 degrees (5.9%). There were three pseudarthroses, one infection, and no rod breakage. CONCLUSION: pseudarthrosis rate of 2.7% and loss of correction of 5.9% are comparable with or better than those in previous reports using autogenous bone graft and either segmental or nonsegmental instrumentation.
- - - - - - - - - -
ranking = 1
keywords = breakage
(Clic here for more details about this article)

2/2. Survivorship analysis of pedicle spinal instrumentation.

    Between 1985 and 1989, the senior author performed 120 consecutive pedicle instrumentation cases--78 Steffee (VSP) procedures and 42 procedures using Cotrel-Dubousset instrumentation. Posterolateral or posterior fusions using autogenous iliac bone graft were performed across the instrumented vertebrae in all cases. Survivorship analysis was used to calculate a predicted cumulative rate of success for this series of patients over 10 years postoperative follow-up. The criteria of failure of pedicular instrumentation or "death" of an implant were defined as 1) screw bending, 2) screw breakage, 3) infection, 4) loosening of implants, 5) any rod or plate hardware problems, or 6) removal of hardware due to a neurologic complication. Out of 526 pedicle screws (175 Cotrel-Dubousset screws, 351 VSP screws) there were 22 problem screws (22/526 = 4.18%). Six screws had bent, none were infected, 16 screws had broken, and none were loose. The 22 problem screw events occurred in 12 patients. In seven patients, the instrumentation failure was an incidental radiographic finding, in that patients had a solid posterolateral fusion. The remaining five patients had screw breakage in association with a pseudarthrosis. life table calculations predicted the survivorship of instrumentation without complications would be 80% at 10 years postoperative follow-up. actuarial analysis predicted the survivorship of solid posterolateral fusion at 90% at 10 years follow-up. This survivorship rate is similar to those predicted at 10 years follow-up for other more widely used orthopedic surgical implants such as total hip arthroplasty components.
- - - - - - - - - -
ranking = 2
keywords = breakage
(Clic here for more details about this article)


Leave a message about 'Pseudarthrosis'


We do not evaluate or guarantee the accuracy of any content in this site. Click here for the full disclaimer.